Project Name:
Report on the Future of the Dethridge Meter

Client:
Goulburn-Murray Water
Project Description:
As part of the decision making process in deciding whether to continue to install and maintain the Dethridge meter and if not what meter should be used to replace them, Thiess Services was engaged to use its Remote Electronic Verification System to test a range of flow meter types in the field for accuracy. Following completion of Thiess Services’ draft report, Hydro Environmental was engaged to:
- review and understand the implications of the Thiess Services Report titled “In Situ Flow Verification Report on Irrigation Structures – Goulburn-Murray Water”;
- provide recommendations based on conclusions drawn from the Thiess Services Report;
- gain an understanding of Water Provider Industry’s perspective on the future metering and the future of the Dethridge meter;
- consult with other users of the Dethridge meter; and
- provide recommendations regarding the future use of the Dethridge meter by Goulburn-Murray Water.
Key Skills Applied:
Irrigation practices, water accounting, technical understanding of irrigation system hydraulics, development of project specifications, report writing and communication skills.